The SANICUBIC 2 SC is a two-motor wastewater lifting pump equipped with a single-channel impeller. Designed for commercial applications, it can lift wastewater from public buildings or shopping centres. This lifting station is available in 4 versions. It comes with a pneumatic remote-control box, which includes an audible and visual alarm.
Single-channel cutting blade
Available in three phases
4 versions: from 125 to 175 m3/h discharge
Tank volume: 1000 litres
IP68 rating*
Find out more

Product details

The Sanicubic 2 SC is a wastewater lifting pump that comes with 2 IP68 certified motors, each with a single channel high performance cutting blade. The Sanicubic 2 SC wastewater lift pump is currently available in 4 different versions for 4 high volume lifting performances. This Sanicubic 2 SC pump has a DN 150 inlet for lifting large volumes of wastewater from commercial environments.

The SFA wastewater lift pump is delivered with a remote-control box as well as an audible and visual alarm for added safety and peace of mind. This SFA wastewater lift pump is designed for easy servicing and regular maintenance. The Sanicubic 2 SC comes with a standard 2-year warranty.

With 60 years of expertise and innovation, Sanicubic 2 SC is designed, made, and tested in France.

Benefits of installing the Sanicubic 2 SC pump:
This pump comes equipped with a single-channel impeller
It is currently available in three phases
It has 4 versions ranging from 125 to 175 m3/h of discharge
Can handle water temperatures of up to 55°C (5min max)
This lifting station also comes with an audible and visual alarm for added safety

Applications of the Sanicubic 2 SC Pump:
Restaurants, foodservice establishments, office complexes, hotels, resorts, shopping centres, malls, factories, warehouses, schools, hospitals, sports centres, and government buildings.

Why choose Sanicubic 2 SC pump?
High Capacity: The Sanicubic 2 SC is designed to handle a higher volume of waste and water, making it suitable for larger residential properties, commercial buildings, and multi-unit installations.
Dual Motors: Equipped with two powerful motors, the Sanicubic 2 SC provides redundancy and ensures continuous operation. If one motor fails, the second can continue to operate, enhancing reliability.
Integrated Non-Return Valves: The unit includes integrated non-return valves to prevent backflow, ensuring that wastewater moves in the right direction and preventing contamination.
Adaptability to Different Waste Types: The pump is capable of handling various types of waste, including grey water and black water, making it a versatile solution for diverse applications.
IP68 Rated: The Sanicubic 2 SC is IP68 rated, indicating its high level of protection against dust and water, making it suitable for use in challenging environments.

Frequently Asked Questions (FAQs):
Q 1. What waste can the Sanicubic 2 SC pump handle?
A: The Sanicubic 2 SC pump is designed to handle all types of wastewater, including black water from toilets and grey water from sinks, showers, and washing machines.

Q 2. Where can the Sanicubic 2 SC pump be installed?
A: It can be installed in basements, utility rooms, garages, and other locations where traditional gravity drainage is not feasible. The station can also be installed below ground level in a pit.

Q 3. What is the maximum discharge height for the Sanicubic 2 SC pump?
A: The Sancubic 2 SC pump has 4 different versions, which can pump wastewater from 10 m up to 22 m vertically.
Technical specification

Sanicubic 2 SC

  • Version
  • Version
  • Version
  • Version
  • Sanicubic 2 SC3.0 T
  • Version
  • Sanicubic 2 SC4.0 T
  • Version
  • Sanicubic 2 SC5.5 T
  • Version
  • Sanicubic 2 SC7.5 T

Materials

  • Shaft
  • Tank
  • Pump housing
  • Seal
  • Motor housing
  • Impeller
  • Shaft
  • Shaft
  • Tank
  • Tank
  • Pump housing
  • Pump housing
  • Seal
  • Seal
  • Motor housing
  • Motor housing
  • Impeller
  • Impeller
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200
  • Shaft
  • Stainless steel
  • Tank
  • PE HD
  • Pump housing
  • EN-GJL-200
  • Seal
  • carbon/ceramic
  • Motor housing
  • EN-GJL-200
  • Impeller
  • EN-GJL-200

Electrical features

  • Number of motor(s)
  • Socket included
  • Voltage (V)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • IP Rating
  • Electrical class
  • Motor insulation class
  • Mode of operation
  • Current
  • Length of cable-control box (m)
  • Number of pumps
  • Type of control box
  • Number of motor(s)
  • Number of motor(s)
  • Socket included
  • Socket included
  • Voltage (V)
  • Voltage (V)
  • Frequency (Hz)
  • Frequency (Hz)
  • Power consumption P1 (W)
  • Power consumption P1 (W)
  • Power output P2 (W)
  • Power output P2 (W)
  • Revolution per minute (RPM)
  • Revolution per minute (RPM)
  • Maximum current (A)
  • Maximum current (A)
  • IP Rating
  • IP Rating
  • Electrical class
  • Electrical class
  • Motor insulation class
  • Motor insulation class
  • Mode of operation
  • Mode of operation
  • Current
  • Current
  • Length of cable-control box (m)
  • Length of cable-control box (m)
  • Number of pumps
  • Number of pumps
  • Type of control box
  • Type of control box
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 4000
  • Power output P2 (W)
  • 3000
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 6.9
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • ZPS 2 case
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 5500
  • Power output P2 (W)
  • 4000
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 11.2
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • ZPS 2 case
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 6300
  • Power output P2 (W)
  • 5500
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 12.1
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • ZPS 2 case
  • Number of motor(s)
  • Dual motor
  • Socket included
  • no
  • Voltage (V)
  • 400
  • Frequency (Hz)
  • 50-60
  • Power consumption P1 (W)
  • 8700
  • Power output P2 (W)
  • 7500
  • Revolution per minute (RPM)
  • 1400
  • Maximum current (A)
  • 16.9
  • IP Rating
  • IP56
  • Electrical class
  • I
  • Motor insulation class
  • F
  • Mode of operation
  • S3 25 %
  • Current
  • Three-phase
  • Length of cable-control box (m)
  • 3,5
  • Number of pumps
  • 2
  • Type of control box
  • PS2 System case

Hydraulic

  • Max. Head (m)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Inlet diameter DN (mm)
  • Discharge diameter DN
  • Ventilation diameter DN
  • Total volume (L)
  • Useable volume (L)
  • Free passage (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of activation
  • Max. Head (m)
  • Max. Head (m)
  • Max. flow rate (m³/h)
  • Max. flow rate (m³/h)
  • Number of inlets
  • Number of inlets
  • Inlet diameter DN (mm)
  • Inlet diameter DN (mm)
  • Discharge diameter DN
  • Discharge diameter DN
  • Ventilation diameter DN
  • Ventilation diameter DN
  • Total volume (L)
  • Total volume (L)
  • Useable volume (L)
  • Useable volume (L)
  • Free passage (mm)
  • Free passage (mm)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Max. temperature of the pumped liquid (5 min) (° C)
  • Type of impeller
  • Type of impeller
  • Type of activation
  • Type of activation
  • Max. Head (m)
  • 10
  • Max. flow rate (m³/h)
  • 120
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 80
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic
  • Max. Head (m)
  • 13
  • Max. flow rate (m³/h)
  • 140
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 80
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic
  • Max. Head (m)
  • 18
  • Max. flow rate (m³/h)
  • 160
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 100
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic
  • Max. Head (m)
  • 22
  • Max. flow rate (m³/h)
  • 165
  • Number of inlets
  • 1
  • Inlet diameter DN (mm)
  • 150
  • Discharge diameter DN
  • 100
  • Ventilation diameter DN
  • 100
  • Total volume (L)
  • 1000
  • Useable volume (L)
  • 500
  • Free passage (mm)
  • 100
  • Max. temperature of the pumped liquid (5 min) (° C)
  • 55°C
  • Type of impeller
  • single-channel
  • Type of activation
  • pneumatic

Logistics

  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • Gross weight (kg)
  • 370
  • Gross weight (kg)
  • 385
  • Gross weight (kg)
  • 400
  • Gross weight (kg)
  • 425

General description

  • EAN code
  • Factory code
  • EAN code
  • EAN code
  • Factory code
  • Factory code
  • EAN code
  • 3308815079073
  • Factory code
  • CUBIC2SC3-0T
  • EAN code
  • 3308815079080
  • Factory code
  • CUBIC2SC4-0T
  • EAN code
  • 3308815079097
  • Factory code
  • CUBIC2SC5-5T
  • EAN code
  • 3308815079103
  • Factory code
  • CUBIC2SC7-5T
Quality

Buy with confidence

  • Experts Since 1958

    Creator of the Sanibroyeur macerating toilet.

  • Tailored Support

    Our team of experts is at your service.

  • Made in France

    Many products have received the Made in France label.

  • Performance and Reliability

    Technologies and materials that ensure efficiency and longevity.